Disclosure: this guide contains one affiliate link, marked in the equipment section. FoxyEco may earn a commission if you buy through it, at no extra cost to you. PG&E programs are described for information; FoxyEco has no relationship with PG&E.
Short answer: a PG&E Public Safety Power Shutoff (PSPS) is a planned de-energization during dangerous wind and dry conditions. PG&E says it aims to notify potentially affected customers starting about 48 hours before power is turned off, with follow-up alerts as the forecast firms up. Power comes back only after the weather passes and crews have checked the lines, so plan for at least one full day and preferably 2 to 3 days. For most households that means a battery sized for the refrigerator, communications and any medical device for 48 hours, a safe recharge or generator plan for longer, and enrolment in the right PG&E programs before fire season.
This guide is specific to PG&E territory in Northern and Central California. For the general method of measuring loads and turning them into battery capacity, see How to measure your essential loads and How to size a home backup battery.
How a PSPS differs from an ordinary outage
- It is scheduled. PG&E’s 2026 notification materials describe “Watch” and “Warning” alerts by text, phone call and email, beginning roughly 2 days out where forecasts allow. Weather can change quickly, so notice may be shorter.
- It ends on PG&E’s timeline, not the weather’s. After the wind event, crews patrol de-energized lines for damage before restoring service. Restoration can therefore follow the end of the wind by many hours, and large events can take longer.
- It is not the only fire-season outage. On circuits with Enhanced Powerline Safety Settings (EPSS), protective equipment trips the line automatically when it senses a fault. Those outages happen without advance notice, which is why a backup plan that depends on a PSPS alert to charge the battery is incomplete.
- Medical Baseline customers are included. PG&E’s 2026 releases note that Medical Baseline customers can be within shutoff areas. They receive additional notifications, and PG&E says staff may follow up with calls or in-person visits when a customer has not confirmed receipt.
Step 1: Get on the right lists before fire season
- Update your contact details in your PG&E account and sign up for PSPS alerts for every address you care about, including a parent’s home. Non-account holders can sign up for address alerts.
- If anyone in the home relies on powered medical equipment, apply for the Medical Baseline program. It brings extra advance notice and lower rates. The application needs a qualified medical practitioner’s certification.
- Check your address on PG&E’s wildfire safety progress map. It shows whether your premises is in a High Fire-Threat District and on an EPSS circuit, which matters for rebate eligibility.
Step 2: Check PG&E’s backup power programs
PG&E runs several programs that can reduce the cost of backup equipment. Terms and funding change, so treat this as a checklist and confirm every detail on PG&E’s own pages before you buy.
- Generator and Battery Rebate Program. For residential or business customers in Tier 2 or Tier 3 High Fire-Threat Districts who are served by an EPSS-enabled circuit. The product must be on PG&E’s qualified product list (portable generators must also be CARB-compliant), bought new, and delivered before you apply; one rebate per household. Secondary sources in 2026 report a base rebate with a larger amount for CARE and FERA customers; confirm the current amount on PG&E’s page, because the figures we found disagree.
- Portable Battery Program. A separate program for customers who rely on electricity for medical needs and meet outage-history criteria. Qualifying customers receive a battery delivered by PG&E.
- Backup Power Transfer Meter. PG&E has offered a meter-collar device that lets an eligible customer connect a compatible portable generator to the home safely, without a separate transfer switch. Eligibility and product requirements are on PG&E’s program page.
Buy after checking eligibility, not before. A rebate application that fails because the model was not on the qualified list or the address was not on an eligible circuit is a common and avoidable disappointment.
Step 3: Size the battery for a 48-hour event
A typical PSPS plan for a Bay Area or Sierra foothill home covers a refrigerator, internet, lights, phone charging and sometimes a CPAP or oxygen concentrator. The worksheet below is an example of what a household might record with a plug-in energy meter over 48 hours before fire season. It is illustrative, not a FoxyEco test; replace every value with your own readings.
| Load | Example meter reading | Wh per day | Start-up surge |
|---|---|---|---|
| Refrigerator | 2,300 Wh over 48 hours | 1,150 | ~600 W (assumed) |
| CPAP, no heated humidifier | 40 W for 8 hours | 320 | n/a |
| Router and modem | 18 W for 24 hours | 432 | n/a |
| LED lights and phone charging | about 360 Wh per evening | 360 | n/a |
| Total | 2,262 |
Following the sizing guide with 88% inverter efficiency, 20 W of inverter idle draw and a 15% reserve, those loads need about 3,050 Wh per day from the battery, or about 7.2 kWh of nominal storage for 48 hours with no recharge. With 400 W of panels at 4.5 peak sun hours and a 75% derate, the requirement falls to about 4 kWh.
Two California-specific adjustments apply. Smoke and haze during fire weather can cut solar output well below a clear-sky estimate, so do not count on full harvest. And many foothill homes are on a 240 V well pump; if water matters, the plan needs a 120/240 V source and a transfer switch, which moves you out of the single portable station category.
For oxygen concentrators and other high-draw medical devices, ask the equipment supplier for the device’s running and start-up power and whether it supports battery operation. PG&E’s medical device preparedness page and your supplier are the right sources, not a product listing.
Step 4: Choose battery, generator or both
A battery is silent, can run indoors and needs no fuel, which matters during red-flag conditions when burn bans and fuel availability can be issues. A generator provides energy for as long as fuel lasts. The broader trade-offs are in home battery vs dual-fuel generator; for households with a compatible EV, see vehicle-to-home vs a home battery.
If you use a generator, follow CPSC guidance without exception: outdoors only, at least 20 feet from the home, with exhaust pointed away from doors, windows and vents. Never run it in a garage, carport, basement or shed, even with the door open. Install battery-operated carbon monoxide alarms. Connect to house circuits only through a transfer switch, interlock or PG&E-approved transfer meter installed by a licensed electrician; backfeeding through an outlet can injure line crews working on what should be a dead line. Store fuel away from structures, and remember that hot engines and spilled fuel are ignition sources in exactly the conditions that trigger a PSPS.
Step 5: Equipment to compare
For a 48-hour refrigerator-and-essentials plan, the practical range is a 2 kWh class LiFePO4 power station with one expansion battery, or a single 3 to 4 kWh unit, plus portable panels whose voltage and current match the station’s solar input. Before buying any model, check three things against this guide: that it is on PG&E’s qualified product list if you intend to apply for the rebate, that its continuous and surge output cover your largest simultaneous loads, and that it can recharge from a car or generator if the sky is smoky. If you are comparing BLUETTI’s expandable models, review BLUETTI's current US range and expansion batteries against your own worksheet rather than a bundle headline. Comparable stations from other makers are shortlisted in the best portable power stations for home backup, and the storage routine between events is covered in where to store a portable power station.
Step 6: A pre-season routine
- In late spring, charge the battery to the level its manual recommends for readiness, test every cable and adapter, and run the planned loads for an hour.
- When a PSPS Watch arrives, top up the battery, freeze water bottles to add thermal mass to the freezer, charge phones and power banks, and fill vehicle fuel tanks.
- During the event, keep the refrigerator closed, run the battery’s AC output only when needed if your list allows, and log the state of charge morning and evening so you know when to shed loads.
- Know where PG&E’s Community Resource Centers open during an event for device charging and supplies, and decide in advance the point at which you will go to one or to another powered location.
Limits
PSPS scope, notice and duration vary by event and are set by PG&E based on forecasts. Program rules, rebate amounts and eligible products change; this guide does not guarantee eligibility. Medical planning belongs with your clinician and equipment supplier. Federal tax credits for home batteries under IRC Section 25D ended for expenditures after 31 December 2025; see the 25D update before counting on any federal incentive.